  1.  
  2.                         ScanTek 3.4
  3.  
  4.                     A scanner driver for
  5.                Microtek, Highscreen and Mustek
  6.                       Flatbed Scanner
  7.  
  8.  
  9.             © Copyright 1995/96/97 Waldemar Zöhner
  10.  
  11.                   Get It, Feel It, Love It
  12.  
  13.  
  14.  Overview
  15. ----------
  16.  
  17.  The ScanTek scanner driver has the following features:
  18.  
  19.  1. Support of the following SCSI Microtek scanner models:
  20.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  21.         ScanMaker E3, ScanMaker 35t, ScanMaker E6,
  22.         Highscreen PerfectScan, Highscreen HighScan
  23.  
  24.     Support of the following SCSI Mustek scanner models:
  25.         Three Pass Scanners:
  26.         6000CX, 8000CX (not tested), 12000CX (not tested) all should work
  27.  
  28.         One or Single Pass Scanners:
  29.         6000SP, 8000SP (not tested), 12000SP (not tested) all should work
  30.         6000CZ (not tested), 8000CZ (not tested)
  31.  
  32.         600IISP, 800IISP (not tested) all should work
  33.  
  34.     If your scanner is not mentioned in the list above try it and
  35.     give me a response whether it works or not.
  36.  
  37.     Attention: In recent times Mustek has changed the scanner firmware.
  38.                I urge you to test Mustek scanners with your Amiga
  39.                configuration before buying it.
  40.  
  41.                Mustek scanners have a critical SCSI interface. It
  42.                was reported to me that these scanners may not work
  43.                with the A2091 and A3000(T) internal SCSI interface.
  44.                It is possible that these scanners do not work with
  45.                other SCSI host adapters, either.
  46.                But the Mustek 6000CX works in combination with an
  47.                Oktagon SCSI host adapter.
  48.                Be sure to disable reselection for Mustek scanners
  49.                on your SCSI host adapter. Otherwise your system may
  50.                not boot.
  51.  
  52.                The current models of Mustek 12000SP are no longer
  53.                supported. The reason is the incompatibility of the
  54.                scanner firmware with the programming documentation.
  55.                There is no information available from Mustek.
  56.  
  57.  
  58.     The following scanner models are not supported:
  59.         Microtek V300 (completely new firmware for SCSI-2 scanner standard
  60.                        this scanner is not available in europe),
  61.         Mustek 12000SP (current model, documentation missing)
  62.         Canon, HP, Epson and any parallelport scanner.
  63.  
  64.  
  65.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  66.     three pass color scan, grey, red, green and blue scan.
  67.  
  68.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  69.     midtone, highlight, exposure time and scanning speed for download to the
  70.     scanner.
  71.  
  72.  4. Download of a color look up table (gamma correction table ) to the scanner
  73.     supported.
  74.  
  75.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  76.     the scanned image is independent from the RAM size. After the scanning
  77.     process it is possible to start an external program.
  78.  
  79.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  80.     but Kickstart 3.0 is recommended.
  81.  
  82.  7. Sizeable preview window in black/white or grey scale. Color preview
  83.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  84.     There are much more skilled programs to view and manipulate the scanned
  85.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  86.     want to do sophisticated postproduction)
  87.  
  88.  8. ARexx support
  89.  
  90.  9. Screenmode requester to define custom screen for working. The actual public
  91.     screen is supported as well
  92.  
  93.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  94.      connectable scanners.
  95.  
  96.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  97.      gvpscsi.device V4.5.
  98.  
  99.  12. ScanTek is written using SAS C 6.55.
  100.  
  101.  13. ScanTek is SHAREWARE.
  102.  
  103.  14. The non registered version of ScanTek is a full working version, but all
  104.      scanned images have black lines to motivate you to register.
  105.      Additionally the maximum size of the preview is restricted.
  106.  
  107.  
  108.  History
  109. ---------
  110.  
  111.  V3.4  21 October 1997
  112.  
  113.    - Support of Transparency Adapter (Slide Kit Unit)
  114.    - Prevent system lockup during startup on Dataflyer SCSI+ host
  115.      adapter
  116.  
  117.  
  118.  V3.3   1 August 1997
  119.  
  120.    - Detection of ScanMaker35t+ introduced 
  121.    - Faster preview scanning process on some scanner models
  122.    - "Accurate Coordinates" support for ScanMaker E6 and compatible
  123.  
  124.  
  125.  V3.2   8 June 1997
  126.  
  127.    - Workaround for surfsquirrel.device to avoid SCSI bus hangup
  128.    - AREXX scripts: Load scanned pictures into 
  129.                     ImageFX:   ST2ImageFX.strx
  130.                     ArtEffect: ST2ArtEffect.strx
  131.  
  132.  
  133.  V3.1  19 May 1997
  134.  
  135.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  136.    - Recognition of Highscreen RealScan (300dpi) introduced
  137.    - Activation of newly opened windows works now correct
  138.  
  139.  
  140.  V3.0   16 Apr. 1997
  141.  
  142.    - AREXX support
  143.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  144.      IFF File
  145.    - Handling of Microtek ScanMaker E6 enhanced
  146.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  147.                and some Mustek scanner models are now correct.
  148.                This bug could lead to images that where to light.
  149.                Grey preview of color image now work with all specified
  150.                settings.
  151.  
  152.  
  153.  V2.10 26 Mar. 1997
  154.  
  155.    - Full size preview on 400 dpi Mustek scanners adjustable
  156.  
  157.  
  158.  V2.9   9 Feb. 1997
  159.  
  160.    - Look Up Table Window redesigned to ensure font sensitivity
  161.  
  162.  
  163.  V2.8  11 Jan. 1997
  164.  
  165.    - New icons for ScanTek
  166.    - Recognition and handling of new Mustek scanners enhanced
  167.    - Minior bug fixes
  168.    - Introduction of the ScanTek Support WebSite
  169.  
  170.  
  171.  V2.7  6 Dec. 1996
  172.  
  173.    - Recognition and handling of new Mustek scanners enhanced
  174.    - Recognition of Microtek ScanMaker E6 adapted
  175.  
  176.  
  177.  V2.6  30 Oct. 1996
  178.  
  179.    - Full support of Mustek one pass scanners
  180.    - Recognition of Mustek scanners enhanced
  181.  
  182.  
  183.  V2.5  5 Oct. 1996
  184.  
  185.    - Workaround to handle strange color mode behaviour of Mustek
  186.      one pass scanners
  187.    - Reverse scanning in black and white mode introduced
  188.  
  189.  
  190.  V2.4 10 Sept. 1996
  191.  
  192.    - Support of Mustek SCSI one pass color scanners in color mode and
  193.      parameter ranges.
  194.    - ScanTek can now open its GUI windows on the actual public screen.
  195.  
  196.  
  197.  V2.3  6 Sept. 1996
  198.  
  199.    - Color Preview on Cybergraphix screens in true color mode
  200.      (15, 16 or 24 bit) for onepass flatbed scanners
  201.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  202.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  203.    - Change and recall of predefined resolution values
  204.  
  205.  
  206.  V2.2 26 July 1996
  207.  
  208.    - Enhanced support for Mustek scanners
  209.      "Exposure Time" and "Contrast" parameters are now correct
  210.    - Gamma value "All" now works on threepass scanner
  211.    - Alternative Black/White scanning mode
  212.  
  213.  
  214.  V2.1  5 July 1996
  215.  
  216.    - Preview now fully supported for Mustek 6000CX
  217.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  218.  
  219.  
  220.  V2.0  30 Apr. 1996
  221.  
  222.    - Preview in color mode with proper options values
  223.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  224.    - X and Y Aspect Ratio in color images is correct now
  225.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  226.    - Lookup Table command supported (Gamma Correction on certain scanner
  227.      possible)
  228.    - Scanning Frame Setting is now more intuitive
  229.    - Reverse image scanning supported (only on certain scanners possible)
  230.    - Accurate scanning supported. Scanning frame is now more precise.
  231.  
  232.  
  233.  V1.3  25 Feb. 1996
  234.  
  235.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  236.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  237.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  238.    - No start of the external program, if the scanning process is aborted
  239.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  240.      Preview image should look better now.
  241.    - "Main Control" window and gadgets modified
  242.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  243.  
  244.  
  245.  V1.2   3 Jan. 1996
  246.  
  247.    - Debug output data revised and enhanced
  248.    - Max Frame Setting setting introduced
  249.    - Start of external program possible
  250.    - Window positions are remembered and saved
  251.    - Configuration file enhanced
  252.  
  253.  
  254.  V1.1  17 Dec. 1995
  255.  
  256.    - detection of Microtek scanner via SCSI inquiry enhanced
  257.    - stepping of resolution slider adapted to expanded base resolution
  258.    - calculation of scanning frame size data modified
  259.  
  260.  
  261.  V1.0  30 Nov. 1995
  262.  